Mobile Phone Attachment for Assessment of Capillary Refill Time
Click to view full size
Preview 1

Description

The information and models provided in this upload are the result of a nine-month Mechanical Engineering capstone at the University of Washington. The goal of this project was to create a quantitative, accurate means of measuring capillary refill time (https://www.nlm.nih.gov/medlineplus/ency/article/003394.htm) (CRT) in children. The provided solution uses a clothespin-like apparatus and a smartphone camera to apply blanching pressure to a subject's fingertip and detect changes in skin color.The procedure closely follows that of the nail blanch (https://www.nlm.nih.gov/medlineplus/ency/imagepages/9154.htm) test, substituting the hand and eye of an clinician with a mechanical presser and an onboard video-processing algorithm. The device consists of three seperate 3D-printable entities and a companion Android application. Some additional components are required to complete the final device: the smartphone itself (an HTC Desire 620G Dual Sim), a small 12 in-lb torsion spring, and a 21.4 mm x 21.4 mm x 11.75 mm block of clear plastic. The printable components are as follows: Pressure applicator. Clothespin-like in form and function. Uses a torsion spring to provide a known, repeatable amount of force. Phone case. Tailored for a loose press fit onto HTC Desire. Mounting points (paired journal bearings) for presser located on back of case. Empty windowframe underneath rear camera for clear plastic window to drop into. Pin. Joins applicator to phone case and allows for rotation. An early version of the Android app used to interface with the device is available. The app prompts the user to apply and release pressure, takes a video of the finger during and after the process, and performs colorimetric analysis on the video data to determine CRT. Please contact creator personally for further information.

From NIH 3D

Model source and downloads

This page preserves searchable metadata and attribution. Use NIH 3D for the current files and source details.

Source creator
Vincent Chan
Source license
Public Domain
Archived copies are shared under the license shown.
View/download on NIH 3D

Makes

See how others have printed this model

Comments

Share your thoughts and ask questions

Sign in to join the conversation

Sign In

Mobile Phone Attachment for Assessment of Capillary Refill Time

From NIH 3D
Likes
0
Views
0
Remixes
0

Category

learning

License

CC0

Published

9/1/2026

Availability

free on NIH 3D